Unionized Free Ammonia (NH₃) vs. TAN: Why pH Shifts Turn Normal Pond Readings Toxic
Total Ammonia Nitrogen alone never tells the whole story. Here is the exact Emerson equilibrium equation and percentage table linking temperature, pH, and gill toxicity.
Standard colorimetric drop or strip test kits used at fish and shrimp ponds measure Total Ammonia Nitrogen (TAN)—the combined sum of ionized ammonium (NH₄⁺) and un-ionized free ammonia (NH₃). Yet fish and shrimp gills are primarily damaged by un-ionized free NH₃, which crosses biological membranes easily.
Interactive Toxic Free Ammonia (NH₃) Calculator
Emerson Equilibrium · Free Tool* Aqueous NH₃/NH₄⁺ ionization equilibrium computed per Emerson et al. (1975) and Bower & Bidwell (1978). See full peer-reviewed references below.
1. The Emerson & Bower–Bidwell Equilibrium
Because free NH₃ toxicity depends non-linearly on pH and temperature, two ponds with the exact same colorimetric TAN kit reading can be in completely different safety zones. Inside BioFloc Management and AquaSim, unionized NH₃ is computed with the standard Emerson et al. (1975) / Bower & Bidwell (1978) equilibrium:
pKa = 0.09018 + 2729.92 / T(K)
fractionNH3 = 1 / (10(pKa − pH) + 1)
Free NH₃-N (mg/L) = TAN (mg/L) × fractionNH3
2. Percentage of Toxic Free NH₃ Across pH & Temperature
Every increase of 1.0 pH unit increases the toxic unionized ammonia fraction nearly tenfold at moderate freshwater temperatures:
| Water pH | 20 °C | 25 °C | 28 °C | 31 °C |
|---|---|---|---|---|
| pH 6.8 | 0.25% | 0.36% | 0.44% | 0.54% |
| pH 7.2 | 0.62% | 0.89% | 1.10% | 1.34% |
| pH 7.6 | 1.55% | 2.21% | 2.71% | 3.31% |
| pH 8.0 | 3.81% | 5.37% | 6.54% | 7.91% |
| pH 8.4 | 9.04% | 12.47% | 14.95% | 17.76% |
3. Worked Contrast: Why 2.0 mg/L TAN Can Be Safe at Dawn and Lethal by Afternoon
Consider an outdoor biofloc tilapia or whiteleg shrimp pond at 28 °C where your test kit reads TAN = 2.0 mg/L:
- Early morning (pH 7.0): free NH₃ fraction is 0.69%, giving 0.014 mg/L NH₃-N (within the safe threshold below 0.025 mg/L).
- Late afternoon algae/CO₂-stripping swing (pH 8.2): free NH₃ fraction rises to 9.98%, pushing free ammonia to 0.200 mg/L NH₃-N — roughly 14.4× higher from the exact same TAN reading!
4. Practical NH₃ Safety Thresholds & Operator Response
| Free NH₃-N Range | Status | Immediate Pond / Tank Action |
|---|---|---|
| < 0.025 mg/L | Safe | Maintain normal feeding and C:N routine; log trend weekly |
| 0.025 – 0.05 mg/L | Caution | Pause feed increases; inspect pH swing, alkalinity, and biofilter DO |
| 0.05 – 0.20 mg/L | Danger | Cut feeding, maintain full aeration, apply split C:N carbon dose or partial water exchange |
| ≥ 0.20 mg/L | Lethal | Stop feeding immediately; emergency clean low-pH water exchange + maximum aeration |
Next emergency calculators: calculate exact Biofloc C:N molasses dosing, stop Brown Blood Disease with our Nitrite (NO₂⁻) Salt Shield Calculator, or size a commercial loop with the RAS Biofilter & Oxygen Sizing Calculator.
* Scientific & Engineering References
- Emerson, K., Russo, R.C., Lund, R.E., & Thurston, R.V. (1975). Aqueous ammonia equilibrium calculations: effect of pH and temperature. Journal of the Fisheries Research Board of Canada, 32(12), 2379–2383. DOI: 10.1139/f75-274
- Bower, C.E., & Bidwell, J.P. (1978). Ionization of ammonia in seawater: effects of temperature, pH, and salinity. Journal of the Fisheries Research Board of Canada, 35(7), 1012–1016. DOI: 10.1139/f78-165
- Timmons, M.B., Guerdat, T., & Vinci, B.J. (2018). Recirculating Aquaculture (4th ed.). Ithaca Publishing Company — chronic and acute free-NH₃ safety thresholds for commercial finfish.
Download BioFloc Management (11 languages) and AquaSim free on Google Play, or book a 1-on-1 engineering review.