Guide 05 · Commercial RAS Mass Balance

RAS MBBR Biofilter, Stocking Density, Feeding & Oxygen Sizing Calculator

Most equipment quotes size biofilters in isolation. Real RAS engineering couples tank volume, peak stocking density, daily feed protein %, TAN nitrogen load, MBBR media volume, oxygen demand, and alkalinity consumption into one mass balance.

Author: Mantas Brazauskas — Commercial African catfish RAS farmer · Biofloc researcher (UAB Aquaculture) Updated: November 23, 2026 Available languages on main portal: English · Bahasa Indonesia · Tiếng Việt · Tagalog · हिन्दी · বাংলা · Lietuvių

In Recirculating Aquaculture Systems (RAS), fish do not load a biofilter by swimming—they load it by eating protein. Yet many farm plans and supplier quotes size an MBBR biofilter by a crude percentage of tank volume without checking how peak biomass density, feed protein %, temperature-dependent nitrification rates, oxygen supply, and alkalinity interact.

Coupled RAS Biofilter, Density, Feed & O₂ Calculator

Free Preliminary Sizing · Timmons & Ebeling Mass Balance
MBBR Media Volume Needed
12.1 m³
Min. reactor tank (50% fill): 24.1 m³
Peak Daily Feed & TAN Load
2.90 kg TAN/d
Feed: 75.0 kg/d · Density: 50.0 kg/m³
Coupled O₂ Demand (Fish + Biofilter)
41.0 kg O₂/d
Peak post-feed: 2.39 kg O₂/hr
Temp-Adjusted Nitrification & O₂ Sat.
0.48 g/m²·d
100% Air O₂ sat. at 26 °C: 8.1 mg/L
Daily Alkalinity (NaHCO₃)
34.8 kg/day
20.7 kg CaCO₃/d destroyed by nitrifiers
Fish vs. Biofilter O₂ & Area
18.8 + 22.2 kg
Active biofilm area: 6,030 m²
Commercial Intensive RAS Zone (50.0 kg/m³): Verify drum-filter micron sizing, CO₂ stripping tower capacity, and 100% standby oxygenation before committing capital to equipment.
Building or upgrading a commercial RAS? Download the locked offline Excel pack or request an independent full-hydraulic & supplier-quote audit:

* Preliminary engineering estimate based on Timmons, Guerdat & Vinci (2018), Recirculating Aquaculture (4th ed.), Benson & Krause (1984) O₂ saturation equilibrium, and Brazauskas & Povilaitis (2026), Water 18(19), 2483. See full scientific & engineering references below.

1. Why Biofilter Sizing Alone Causes Expensive RAS Failures

When investors compare RAS equipment quotations, suppliers often highlight a large plastic media volume while ignoring the four coupled constraints that actually cap farm output:

  • Protein-Driven Nitrogen Load: Raising feed protein from 32% to 45% increases daily TAN excretion by 40% at the exact same feeding weight (P_TAN = Feed × Protein% × 0.092).
  • The 50% MBBR Fill Trap: Moving-bed media must tumble freely to shear old biofilm and exchange oxygen. If you need 12.9 m³ of K1 media, your biofilter reactor tank must hold at least 25.8 m³ of working water volume—not 13 m³.
  • Hidden Biofilter Oxygen Demand: Autotrophic nitrification consumes 4.57 kg of O₂ per kg of TAN oxidized, plus heterotrophic breakdown of fine solids. In many commercial RAS loops, the biofilter consumes as much oxygen as the fish themselves.
  • Alkalinity Collapse Stops Nitrification: Every 1 kg of TAN oxidized destroys 7.14 kg of CaCO₃ alkalinity (~12 kg of NaHCO₃). When alkalinity falls below 60 mg/L CaCO₃, pH crashes and toxic nitrite spikes even if the biofilter is physically huge.

2. What This Preliminary Calculator Covers vs. Full Engineering Audit

This free calculator gives you an honest first-pass mass balance for MBBR media, TAN, oxygen, and alkalinity. Before committing capital to a commercial RAS build or upgrade, a full independent engineering review through UAB Aquaculture (combining Mantas Brazauskas's wet-system biology with Mindaugas Brazauskas's 15+ years of civil & RAS infrastructure engineering) additionally verifies:

  • Full hydraulic recirculation turnover (m³/h), pipe head-loss, and electricity kWh/kg fish cost
  • Drum-filter hydraulic capacity & micron screen sizing (preventing heterotrophic biofilter choking)
  • CO₂ stripping tower airflow ratio (G:L) and pure-oxygen cone / LHO transfer efficiency
  • Realistic multi-batch stocking, grading, and CAPEX/OPEX unit economics—with zero equipment sales commissions.

3. Explore All Free Water-Chemistry Calculators

Also try our Biofloc C:N Molasses Calculator, Free NH₃ Ammonia Calculator, and Nitrite Salt Shield Calculator, or test RAS crisis scenarios interactively in AquaSim.

* Scientific & Engineering References

  1. Timmons, M.B., Guerdat, T., & Vinci, B.J. (2018). Recirculating Aquaculture (4th ed.). Ithaca Publishing Company — TAN excretion stoichiometry (0.092 × Feed × Protein%), MBBR nitrification rates, 4.57 g O₂/g TAN nitrification oxygen demand, and 7.14 g CaCO₃/g TAN alkalinity consumption.
  2. Benson, B.B., & Krause, D. (1984). The concentration and isotopic fractionation of oxygen dissolved in freshwater and seawater in equilibrium with the atmosphere. Limnology and Oceanography, 29(3), 620–632. DOI: 10.4319/lo.1984.29.3.0620
  3. Brazauskas, M., & Povilaitis, A. (2026). Biofloc Versus Recirculating Aquaculture Systems: A Sustainability-Oriented Review and Evidence Gap Analysis for African Catfish (Clarias gariepinus). Water, 18(19), 2483. DOI: 10.3390/w18192483
Planning a RAS farm or comparing equipment quotes?

Get an independent engineering audit from practicing RAS farmers & civil engineers at UAB Aquaculture (Lithuania, EU), or test scenarios free in AquaSim.

WhatsApp Direct · +370 650 95053